Study on Problems of Suakin Power Station and Its Proposesd Solutions

Prijzen vanaf
55,99

Uitgelicht

VERGELIJK ALLE AANBIEDERS (2)

Beschrijving

Bol The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer.

Vergelijk aanbieders (2)

Shop
Prijs
Verzendkosten
Totale prijs
58,99
55,99
Gratis
55,99
Naar shop
Gratis Shipping Costs
59,14
Gratis
59,14
Naar shop
Gratis Shipping Costs
Beschrijving (2)
Bol

The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer.

Amazon

Pages: 96, Paperback, LAP Lambert Academic Publishing


Productspecificaties

Merk LAP LAMBERT Academic Publishing
EAN
  • 9786208420796
Maat


Prijshistorie

* Prijshistorie bevat geen data van Amazon.

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
55,99
Naar shop