Heat transfer through parabolic pipe

Prijzen vanaf
47,99

Uitgelicht

VERGELIJK ALLE AANBIEDERS (3)

Beschrijving

Bol The objective of this paper is to present a novel thermal study of absorber/receiver circular pipe of parabolic trough solar collector system for laminar and turbulent (k-¿ model) fluids flow. Using CFD ANSYS FLUENT software, a two-dimensional numerical simulation is performed on the enhanced flow and heat transfer fluid of air in PTC receiver pipe. In both the laminar and turbulent flow regimes, the findings showed significant improvements in heat transfer, velocity and temperature drop also, the pattern of temperature distribution over the pipe absorber is exhibited and velocity vectors, pressure contours, temperature contours are analyzed. Velocity drop increases and pressure drop decreases with increasing distance along center line axis towards outlet line of receiver pipe. The effect of increasing heat flux towards pipe wall is presented; it causes increasing of wall temperature (from 350 to 390 K in laminar flow and from 310 to 325 K in turbulent flow). Additionally, Nu number, Fr, and Cd for heat transfer laminar and turbulent flows fluid were calculated.

Vergelijk aanbieders (3)

Shop
Prijs
Verzendkosten
Totale prijs
47,99
Gratis
47,99
Naar shop
Gratis Shipping Costs
69,64
4,15
73,79
Naar shop
4,15 Shipping Costs
69,64
4,15
73,79
Naar shop
4,15 Shipping Costs
Beschrijving (1)

The objective of this paper is to present a novel thermal study of absorber/receiver circular pipe of parabolic trough solar collector system for laminar and turbulent (k-¿ model) fluids flow. Using CFD ANSYS FLUENT software, a two-dimensional numerical simulation is performed on the enhanced flow and heat transfer fluid of air in PTC receiver pipe. In both the laminar and turbulent flow regimes, the findings showed significant improvements in heat transfer, velocity and temperature drop also, the pattern of temperature distribution over the pipe absorber is exhibited and velocity vectors, pressure contours, temperature contours are analyzed. Velocity drop increases and pressure drop decreases with increasing distance along center line axis towards outlet line of receiver pipe. The effect of increasing heat flux towards pipe wall is presented; it causes increasing of wall temperature (from 350 to 390 K in laminar flow and from 310 to 325 K in turbulent flow). Additionally, Nu number, Fr, and Cd for heat transfer laminar and turbulent flows fluid were calculated.


Productspecificaties

Merk LAP LAMBERT Academic Publishing
EAN
  • 9786630285543
Maat


Prijshistorie

* Prijshistorie bevat geen data van Amazon, Amazon Marketplace.

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
47,99
Naar shop