Framework design materials for implant fixed restorations

Prijzen vanaf
74,95

Uitgelicht

VERGELIJK ALLE AANBIEDERS (2)

Beschrijving

Bol Frameworks must be fabricated from materials and protocols that allow passive and accurate fit between frameworks and implants and/or abutments. CAD/CAM fabricated frameworks generally provide better, more accurate fit than do cast frameworks.Framework design has evolved into a series of clinical and laboratory procedures that incorporate principles of fixed and removable prosthodontics; prostheses are more successful if frameworks are designed consistent with predetermined tooth positions.Frameworks must be designed with adequate space (1.5 to 2 mm) for prosthetic materials: acrylic resin/composite resin/reinforced polymeric materials. Retentive elements for denture base materials should be designed as integral parts of implant frameworks. Adequate thickness is necessary to minimize the potential for denture base fracture. Acrylic resin retention may be accomplished with nail head retentive elements, retentive loops, or undercut areas randomly placed throughout frameworks. Retentive elements should be placed such that they will not interfere with tooth placement.

Vergelijk aanbieders (2)

Shop
Prijs
Verzendkosten
Totale prijs
74,95
Gratis
74,95
Naar shop
Gratis Shipping Costs
79,90
Gratis
79,90
Naar shop
Gratis Shipping Costs
Beschrijving (2)
Bol

Frameworks must be fabricated from materials and protocols that allow passive and accurate fit between frameworks and implants and/or abutments. CAD/CAM fabricated frameworks generally provide better, more accurate fit than do cast frameworks.Framework design has evolved into a series of clinical and laboratory procedures that incorporate principles of fixed and removable prosthodontics; prostheses are more successful if frameworks are designed consistent with predetermined tooth positions.Frameworks must be designed with adequate space (1.5 to 2 mm) for prosthetic materials: acrylic resin/composite resin/reinforced polymeric materials. Retentive elements for denture base materials should be designed as integral parts of implant frameworks. Adequate thickness is necessary to minimize the potential for denture base fracture. Acrylic resin retention may be accomplished with nail head retentive elements, retentive loops, or undercut areas randomly placed throughout frameworks. Retentive elements should be placed such that they will not interfere with tooth placement.

Amazon

Pages: 164, Paperback, LAP Lambert Academic Publishing


Productspecificaties

Merk LAP LAMBERT Academic Publishing
EAN
  • 9786208445980
Maat

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
74,95
Naar shop