Fingernails as a Retrospective EPR Dosimeter: Reducing Mechanical and Background Signals

Prijzen vanaf
62,76

Gesponsorde links

VERGELIJK ALLE AANBIEDERS (2)

Beschrijving

Bol In this study, human fingernails were used to estimate radiation dose by electron paramagnetic resonance (EPR) spectroscopy. The main limitation was the presence of mechanically induced EPR signals generated during nail clipping and sample preparation. Because these signals overlap with the radiation-induced signal, the absorbed dose can be overestimated. Several treatments were therefore applied to reduce the mechanical signal. The results showed that mechanically induced and radiation-induced signals have different microwave power saturation behavior. The mechanical signal faded with time and reached a constant value after about 20 h. Heat treatment at 70°C for 3 h reduced the mechanical signal to the same extent as 20 h at ambient temperature. Among chemical treatments, dithiothreitol produced the lowest mechanical signal. Dose-response curves for nails treated with dithiothreitol for 30 min were more linear and precise than those treated for 5 min. Therefore, for unknown absorbed-dose estimation in fingernail samples using a calibration curve, treatment with dithiothreitol for 30 min is recommended to reduce uncertainty.

Vergelijk aanbieders (2)

Gesponsorde links · Sommige shops betalen ons een vergoeding

Sorteren op:

€ 68,74 € 62,76 Gratis verzending

€ 98,95 € 1,99 verzendkosten Totaal € 100,94

Beschrijving (1)

In this study, human fingernails were used to estimate radiation dose by electron paramagnetic resonance (EPR) spectroscopy. The main limitation was the presence of mechanically induced EPR signals generated during nail clipping and sample preparation. Because these signals overlap with the radiation-induced signal, the absorbed dose can be overestimated. Several treatments were therefore applied to reduce the mechanical signal. The results showed that mechanically induced and radiation-induced signals have different microwave power saturation behavior. The mechanical signal faded with time and reached a constant value after about 20 h. Heat treatment at 70°C for 3 h reduced the mechanical signal to the same extent as 20 h at ambient temperature. Among chemical treatments, dithiothreitol produced the lowest mechanical signal. Dose-response curves for nails treated with dithiothreitol for 30 min were more linear and precise than those treated for 5 min. Therefore, for unknown absorbed-dose estimation in fingernail samples using a calibration curve, treatment with dithiothreitol for 30 min is recommended to reduce uncertainty.


Productspecificaties

Merk Scholars' Press
EAN
  • 9786630535914
Maat


Prijshistorie

* Prijshistorie bevat geen data van Amazon.

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
62,76
Naar shop