Current Harmonic Mitigation Using PV SHAPF With MHCC DFCEA

Prijzen vanaf
53,99

Uitgelicht

VERGELIJK ALLE AANBIEDERS (2)

Beschrijving

Bol The increasing prevalence of Non-Linear Loads (NLLs) inelectrical power systems, driven by devices like rectifiers, variable-speeddrives, and switch-mode power supplies, has introduced significant challengesin transmission systems and PV installations. The resultant voltage andcurrent harmonics disrupt the purity of power signals, emphasizing the needfor effective mitigation strategies. Shunt Active Power Filters (SHAPFs) haveemerged as promising solutions, with their performance dependent on factorslike inverter control, and reference current generation.This research study introduces a Modified Hysteresis CurrentController (MHCC) with a Dual Fundamental Component Extraction Algorithm(DFCEA) designed to enhance the current harmonic mitigation performance of aSHAPF based on a three-level T-type inverter (3LTI). The focus is on improvingperformance under non-sinusoidal voltage conditions, especially in the context ofa PV-linked T-type inverter-based SHAPF (PV-SHAPF). The DFCEA plays acrucial role in isolating fundamental voltage and current components, essentialfor synchronizing phases and generating reference currents tailored to meetPV-SHAPF requirements.

Vergelijk aanbieders (2)

Shop
Prijs
Verzendkosten
Totale prijs
53,99
Gratis
53,99
Naar shop
Gratis Shipping Costs
96,68
Gratis
96,68
Naar shop
Gratis Shipping Costs
Beschrijving (2)
Bol

The increasing prevalence of Non-Linear Loads (NLLs) inelectrical power systems, driven by devices like rectifiers, variable-speeddrives, and switch-mode power supplies, has introduced significant challengesin transmission systems and PV installations. The resultant voltage andcurrent harmonics disrupt the purity of power signals, emphasizing the needfor effective mitigation strategies. Shunt Active Power Filters (SHAPFs) haveemerged as promising solutions, with their performance dependent on factorslike inverter control, and reference current generation.This research study introduces a Modified Hysteresis CurrentController (MHCC) with a Dual Fundamental Component Extraction Algorithm(DFCEA) designed to enhance the current harmonic mitigation performance of aSHAPF based on a three-level T-type inverter (3LTI). The focus is on improvingperformance under non-sinusoidal voltage conditions, especially in the context ofa PV-linked T-type inverter-based SHAPF (PV-SHAPF). The DFCEA plays acrucial role in isolating fundamental voltage and current components, essentialfor synchronizing phases and generating reference currents tailored to meetPV-SHAPF requirements.

Amazon

Pages: 128, Paperback, LAP Lambert Academic Publishing


Productspecificaties

Merk LAP LAMBERT Academic Publishing
EAN
  • 9786204955810
Maat

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
53,99
Naar shop